Milltronics CVCC Manuale delle Istruzioni Pagina 8

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 59
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 7
» Alarm: » 2 multipurpose relays for rate, load, or speed
» 1 Form "C" SPDT contact per relay, rated 5A at 230 V AC
» Communication: » 1 relay, 4PDT used for communication loop dropout,
» rated 1A at 230 V AC
» Display: » illuminated 256 x 128 dot matrix
Communication: » 2 serial ports
» RS232C and ± 20 mA current loop
Enclosure: » NEMA4 style, steel construction with polycarbonate window
» 330 mm W x 406 mm H x 102 mm D
(13" W x 16" H x 4" D)
Shipping Weight: » 11.0 Kg (24.3 lbs), no options
OPTIONS
Cable: » Single load cell, 150m (500 ft) max. 20 AWG, 4 wire shielded,
Belden 8404 or equivalent
» Single load cell, 300m (1000 ft) max. 20 AWG, 6 wire shielded,
Belden 8426 or equivalent
» Dual load cell, 150 m (500 ft) max. 20 AWG, 6 wire shielded,
Belden 8426 or equivalent
» Dual load cell, 300 m (1000 ft) max. 20 AWG, 8 wire shielded,
Belden 8418 or equivalent
» LVDT, 150 m (500 ft) max. 20 AWG, 4 wire shielded,
Belden 8404 or equivalent
» Speed Sensor, 300 m (1000 ft) max. 18 AWG, 3 wire shielded,
Belden 8770 or equivalent
Speed Sensor: » Milltronics MD36 or MD2000A for speed input
LCPA-08 » For connection to MMI-3 or MMI-4 scale configurations
interface:
Incline Compensator: » For variable incline conveyors
Barrier Strips: » For hazardous location belt scales
Enclosure Heater: » Recommended for operating temperatures below -10°C (14°F),
or excessive humidity.
Relay: » Food Grade remote totalizer relay
CVCC: » For bipolar current/RS-232C interface
BIC-II: » For 6 port bipolar current loop/RS-232C or RS-422 interface.
PL-367 2 – 2
Vedere la pagina 7