MOUNTING - LIQUID APPLICATIONS (cont’d)
nipple welded to blind flange
customer flange, flat face only
factory flanged transducer
bolt
gasket
nut
coupling
Customer flanged standpipe. If a metal flange must be welded
to pipe, refer to Liquid \ Applications - Standpipes.
Flanged
Flange, gasket and hardware supplied by customer.
Refer to Liquid \ Applications - Standpipes.
coupling
Blind Flange
Note: Tighten the flange bolts evenly in order to ensure a good seal between
the mating flanges.
Caution: Overtightening can cause performance degradation.